Annual electricity spend
Total U.S. facility electricity cost you want to model, in USD per year.
- Default
- $360,000
- Allowed range
- $10,000–$20,000,000
U.S. dollars per year
GRIDFLEX · CALCULATOR NOTES
A transparent walkthrough of the inputs, arithmetic, and scenario ranges behind GridFlex’s commercial facility calculator.
01 / Inputs
These defaults and limits are read from the same configuration as the live calculator.
Total U.S. facility electricity cost you want to model, in USD per year.
U.S. dollars per year
Your estimate of the annual spend linked to load the selected asset can influence.
Percent of annual electricity spend
The facility’s highest monthly demand, measured in kW.
Kilowatts (kW)
The tariff demand charge used for this scenario, in USD per kW-month.
U.S. dollars per kW-month
The reduction you want to test across the flexible-cost and demand-charge components.
Percent
02 / Formulas
Percent inputs are treated as fractions in the calculation.
Configured illustrative annual value
(annual electricity spend × controllable cost share × peak-reduction assumption)
+ (monthly peak demand × demand charge × 12 × peak-reduction assumption)Scenario peak reduction
monthly peak demand × peak-reduction assumptionThe monthly demand charge is annualized by multiplying by 12 months.03 / Scenario range
Each case uses the same annual-value and peak-reduction formulas above. Other configured inputs stay the same.
Subtract 5 percentage points from controllable cost share and 3 points from peak reduction.
Add 5 percentage points to controllable cost share and 3 points to peak reduction.
Both adjusted values are clamped to their input limits: cost share stays between 0% and 100%, and peak reduction stays between 0% and 50%. For example, a 2% cost share and 1% peak-reduction setting produce 0% for both Low adjustments rather than negative values.
04 / Worked example
The values below are calculated from the live calculator model using its current defaults: $360,000 annual spend, 25% controllable share, 1,000 kW monthly peak, an $18/kW-month demand charge, and 10% peak reduction.
Configured
25% share · 10% peak reductionLow case
20% share · 7% peak reductionHigh case
30% share · 13% peak reduction05 / Limits
Outputs are illustrative scenarios. They are not forecasts, guaranteed savings, revenue commitments, or net ROI. The calculation does not subtract asset or operating costs. Actual outcomes depend on site conditions, tariff structure, asset performance, operating schedules, program eligibility and terms, and market conditions.
Ready to enter assumptions for a facility?
Open the live scenario calculator